Hardness Tester

Rockwell Hardness Tester

2020-06-15


HRS.jpg

Digital Rockwell Hardness Tester, based on the mechanical principle of conical diamond or hard alloy indenter pressing into the sample surface to produce indentation, realizing the material hardness measurement by measuring the depth of the indentation. 

Capable of inspecting the finished or semi-finished parts of the machined sample, it is suitable for high accuracy hardness testing for batches parts with various metal or non-metallic materials. According to statistics, Rockwell hardness testing is the most widely used hardness testing method in metal processing industry, which utilization ratio is more than 70%. With novel appearance, stable performance, intuitive and convenient LCD display, and easy to operate the menu design.  


It is widely used in metal processing and manufacturing, various metal material’s failure analysis and other fields like colleges and research institutions. It is the new type Brinell hardness testing instrument for testing the hardness of the materials like cast iron, steel, soft alloy and so on.


Model

 HRS-150 Digital Rockwell Hardness Tester

Preliminary testing force

98.07Ntolerance±2.0%

Testing force

588.4N980.7N1471Ntolerance±1.0%

Measuring range

HRA20-88HRB20-100HRC20-70HRD40-77HRE70-100HRF60-100HRG30-94HRH80-100HRK40-100HRL

Testing force application Mode

Automatic operation (preliminary test needs manual operation)

Indenter specification

Diamond cone Rockwell indenterΦ1.5875mm steel ball indenter

Display

LCD liquid crystal display

Rockwell scale

HRAHRBHRCHRDHREHRFHRGHRHHRKHRLHRMHRPHRRHRSHRV

Conversion scale

HRAHRBHRCHRDHR15NHR30NHR45NHR15THR30THR45THVHBWHK

Duration time

1~30s

Indication error

0.1HR

Maximum height of specimen

170mm

Distance of indenter to outer wall

165mm

Power supply

AC220V/50Hz

Dimensions

550*220*730mm

Main unit weight

85kg






Model


                                    HRS-150T Cantilever Rockwell Hardness Tester


Preliminary Testing Force

29.4N98.07Ntolerance±2.0%

Testing Force

147.1N294.2N441.3N588.4N980.7N1471Ntolerance±1.0%

Measuring Range

HRA20-88HRB20-100HRC20-70HRD40-77HRE70-100HRF60-100HRG30-94HRH80-100HRK40-100HRL

Testing Force Application Mode

Automatic operation (preliminary test force needs manual operation)

Indenter Specification

Diamond cone Rockwell indenter, Φ1.5875mm steel ball indenter

Display

LCD

Rockwell Scale

HRAHRBHRCHRDHREHRFHRGHRHHRKHRLHRMHRPHRRHRSHRV

Conversion Scale

HVHBWHK

Indication Error

0.01HR

Duration Time

1~30s

Maximum Height of Specimen

200mm

Distance of Indenter to Outer Wall

150mm

Power Supply

AC220V/50Hz

Dimension

700*250*600mm

Main Unit Weight

100kg





Model

HRS-150P Digital Plastic Rockwell Hardness Tester

Preliminary testing force

98.07Ntolerance±2.0%

Testing force

588.4N980.7N1471Ntolerance±1.0%

Measuring range

HRA20-88HRB20-100HRC20-70HRD40-77HRE70-100HRF60-100HRG30-94HRH80-100HRK40-100HRL

Testing force application mode

Automatic operation (preliminary test needs manual operation)

Indenter specification

Φ3.175mm steel ball indenterΦ6.35mm steel ball indenterΦ12.7mm steel ball indenter

Display

LCD

Rockwell scale

HRAHRBHRCHRDHREHRFHRGHRHHRK

Conversion scale

HRAHRBHRCHRDHR15NHR30NHR45NHR15THR30THR45THVHKHBW

Duration time

1~30s(The testing force duration time for plastic Rockwell hardness test is 15 seconds)

Indication error

0.1HR

Maximum height of specimen

170mm

Distance of indenter to outer wall

165mm

Power supply

AC220V/50Hz

Dimensions

550*220*730mm

Main unit weight

85kg





   


        Model

HRS-150-XYZ Automatic Rockwell Hardness Tester

Preliminary testing force

98.07Ntolerance±2.0%

Testing force

588.4N980.7N1471Ntolerance±1.0%

Measuring range

HRA20-88HRB20-100HRC20-70HRD40-77HRE70-100HRF60-100HRG30-94HRH80-100HRK40-100HRL

Testing force application Mode

Automatic operation (preliminary test force need manual operation)

Indentor specification

Diamond cone Rockwell indenter, Φ1.5875mm steel ball indenter

Display

High sensitivity touch screen

Rockwell scale

HRAHRBHRCHRDHREHRFHRGHRHHRKHRLHRMHRPHRRHRSHRV

Conversion scale

HRAHRBHRCHRDHR15NHR30NHR45NHR15THR30THR45THVHBWHK

Duration time

0~99s

Indication error

0.1HR

Maximum height of specimen

300mm

Distance of indenter to outer wall

165mm

Power supply

AC220V/50Hz

Dimension

550*320*750mm

Main unit weight

100kg





   Model

HRS-45A Digital Surface Rockwell Hardness Tester

Preliminary testing force

29.4Ntolerance±2.0%

Testing force

147N294N441Ntolerance±1.0%

Measuring range

HR15N70-91HR30N42-80HR45N20-70HR15T73-93HR30T43-82HR45T12-72

Testing force application Mode

Automatic operation (preliminary test needs manual operation)

Indentor specification

Diamond cone Rockwell indenter, Φ1.5875mm steel ball indenter.

Display

LCD and LED digital tube dual screen display

Rockwell scale

HR15N HR30N HR45N HR15T HR30T HR45T

Conversion scale

HVHBHR

Duration time

1~30s

Indication error

0.1HR

Maximum height of specimen

170mm

Distance of indenter to outer wall

165mm

Power supply

AC220V/50Hz

Dimensions

510*212*730mm

Main unit Weight

80kg






Model

HR-150DT Electronic Rockwell Hardness Tester

Preliminary testing force

98.07Ntolerance±2.0%

Testing force

588.4N980.7N1471Ntolerance±1.0%

Hardness measuring range

HRA20-88HRB20-100HRC20-70HRD40-77HRE70-100HRF60-100HRG30-94HRH80-100HRK40-100

Testing force application Mode

Automatic operation (preliminary test needs manual operation)

Indenter specification

Diamond cone Rockwell indenterΦ1.5875mm steel ball indenter

Display

Classic dial

Rockwell scale

HRAHRBHRCHRDHREHRFHRGHRHHRK

Conversion scale

HVHBHRWHK

Duration time

1~30s

ndication error

0.1HR

Maximum height of specimen

170mm

Distance of indenter to outer wall

165mm

Power supply

AC220V / 50Hz

Dimensions

510*212*700mm

Main unit weight

85kg






Model

HR-150A Manual Rockwell Hardness Tester

Preliminary Testing force

98.07Ntolerance ±2.0%

Testing force

588.4N, 980.7N, 1471N , tolerance ±1.0%

Hardness Measuring range

HRA:20-88HRB:20-100HRC:20-70HRD:40-77HRE:70-100HRF:60-100HRG:30-94HRH:80-100HRK:40-100

Testing Force Application Mode

Manual operation

Indenter specification

Diamond cone Rockwell indenterΦ1.5875mm steel ball indenter

Display

Mechanical dial

Indication error

0.1HR

Indicator scale

0~100C),30~130B

Rockwell scale

HRAHRBHRCHRDHREHRFHRGHRHHRK

Maximum height of specimen

170mm

Distance of Indenter to outer wall

135mm

Dimension

510×212×700mm

Main unit weight

85kg


CONTACT US

E-mail: zhongyi@zhongyi-ndt.com

Tel: +86- 415-6133688

Fax : +86- 415-6133688

Work Time: 9AM--5PM (GMT+8)

Address: No. 5 Tong Xing Rd ,Zhen An Distr.

Dandong, 118011 China

MOBILE WEBSITE